=MOE Type Work Design Intent/Shop Drawings SOP= | =MOE Type Work Design Intent/Shop Drawings SOP= | ||
Please ensure the following points are reviewed & adhered to when reviewing MOE Type Shop drawings designs, anything not inline with these SOP’s please have Drafting team revise prior sending DI for client approval. | |||
*4 hole baseplates by default unless told otherwise | |||
*No Chemical Anchors-only use HDG 12mm screw bolt for concrete fixings | |||
*75mm concrete edge distance will always be achievable onsite unless specifically stated meaning we can use Concrete screws unless reduced edge distance(50mm) is required | |||
*Stainless Steel 180mm Coach screws in all timber areas with SS washer & Nylon separation washer | |||
=Green Rule= | =Green Rule= | ||
When the sum of the Bend length, and straight on the end of bent pipe is 300mm or less; Add 200mm green. Should the straight end of bent pipe is 80mm or less, add 200mm green | When the sum of the Bend length, and straight on the end of bent pipe is 300mm or less; Add 200mm green. Should the straight end of bent pipe is 80mm or less, add 200mm green | ||
Revision as of 04:53, 15 October 2025
PS1 Documentation
An PS1 is an engineering document that's required for all Moddex Product for New Zealand. There are PS1's available to view on the NZ One Drive, or in some cases a specific PS1 is made for an project.
Should you require a PS1 for a project, it will be mentioned in the original handover
Standard PS1 documentation
MOE Type Work Design Intent/Shop Drawings SOP
Please ensure the following points are reviewed & adhered to when reviewing MOE Type Shop drawings designs, anything not inline with these SOP’s please have Drafting team revise prior sending DI for client approval.
- 4 hole baseplates by default unless told otherwise
- No Chemical Anchors-only use HDG 12mm screw bolt for concrete fixings
- 75mm concrete edge distance will always be achievable onsite unless specifically stated meaning we can use Concrete screws unless reduced edge distance(50mm) is required
- Stainless Steel 180mm Coach screws in all timber areas with SS washer & Nylon separation washer
Green Rule
When the sum of the Bend length, and straight on the end of bent pipe is 300mm or less; Add 200mm green. Should the straight end of bent pipe is 80mm or less, add 200mm green