=Design Notes= | =Design Notes= | ||
*Make sure there is a 50mm gap between the closure and the end of the handrail. | |||
<b>Incorrect</b> | |||
[[File:Wrong Bikesafe design.PNG|frameless|400px]] | |||
<b>Correct</b> | |||
[[File:Correct Bikesafe design.jpg|frameless|400px]] | |||
=Design tips= | =Design tips= | ||
Revision as of 02:12, 5 March 2024
Moddex Bikesafe barriers ensure you protect cyclists, especially those travelling at speed, and eliminate or mitigate injury from falls. Bikesafe systems are quick and easy to install, with curved sections to flow with cycle ways.
The smooth continuous top rails help prevent or mitigate injury for both pedestrians and cyclists.
And your cycleway barriers can form part of a cohesive solution. Modular Bikesafe bikeway barriers are designed to integrate easily with our Conectabal and Assistrail range.
With six configurations available in the Bikesafe family, Moddex bikeway barriers offer:
- Continuous full or partial offset barriers for protection across culverts, bridges, headwalls and hazards
- Smooth and continuous top rails for injury prevention
- Curves to flow with bike paths or cycle ways
Bikesafe Systems
- BS10 - Bikeway barrier with offset top rail
- BS20 - Bikeway barrier with offset top rail and midrail
- BS25 - Bikeway barrier with offset top rail and handrail
- BS30 - Bikeway barrier with offset top rail, midrail and bottom rail
- BS35 - Bikeway barrier with offset top rail, handrail and bottom rail
- BS40 - Bikeway barrier with offset top rail and balustrade infill
- BS45 - Bikeway barrier with offset top rail, handrail and balustrade infill
Compliance
Moddex balustrades and handrails are designed and manufactured in accordance with Austroads Guide to Road Design and relevant statutory WHS Codes of Practice/ Guidelines. Galvanized to AS 4792 and AS/NZS 4680:2006 (where applicable).
Common compliances
Design Notes
- Make sure there is a 50mm gap between the closure and the end of the handrail.
Incorrect
Correct
Design tips
Technical data
Stanchion & Rails | Clamp Fittings | Clamp locking screws |
---|---|---|
Steel/grade C250 & 350 | Malleable Cast iron | Stainless Steel (304) |
Stanchion, rails & balustrade | Clamp fittings | Optional |
---|---|---|
G390 Hot Dip Galvanized (min 390g/m2) | Hot-dip Galvanized with patented protective coating on threads | Powder coating and paint specs* |
Dimensions
Diameter | Nominal Thickness |
---|---|
48.3mm OD | 3.2mm |
Thickness | Locking Screws |
---|---|
5.0mm (approx) | M12 x 1.75 x 11mm - DEXX® Drive |
Fixings
Concrete | Structural Steel |
---|---|
M12 galvanized mechanical concrete anchor
FX12113.12.100 Concrete Screw Bolt, M12 x 100mm - Galvanized |
M16 galvanized high tensile bolt set
FX22113.16.050 Structural Bolt, Nut & Washer Assembly, M16 x 50mm - HDG |